CCDYY - B31W202 SEMI-GLOSS PROMAR 200 BASE Y

Product Identification

Product ID:B31W202 SEMI-GLOSS PROMAR 200 BASE Y
MSDS Date:11/01/1995
FSC:8010
NIIN:00F051331
MSDS Number: CCDYY

Responsible Party
SHERWIN-WILLIAMS CO/MARTIN SENOUR CO/ROGERS AUTO
101 PROSPECT AVE N W
CLEVELAND, OH 44115-1042
US

Emergency Phone: 216-566-2917/216-566-2902

Info Phone: 216-566-2902/216-566-2917

Cage: 54636

Contractor
SHERWIN-WILLIAMS CO THE
CLEVELAND, OH 44115-1042 US

Telephone: 800-251-2486/216-566-2242

Cage: 54636

Ingredients

1), CALCIUM CARBONATE,

CAS: 471-34-1

RTECS: FF9335000

Fraction By Weight: 0.5-6%


TITANIUM DIOXIDE, TITANIUM OXIDE (SUSPECTED ANIMAL

CAS: 13463-67-7

RTECS: XR2275000

Fraction By Weight: 9-27%

OSHA PEL 15 MG/CUM

ACGIH TLV: 10 MG/CUM (DUST)


WATER

CAS: 7732-18-5

RTECS: ZC0110000

Fraction By Weight: 40.3-56%


0.25-0.56 LBS/GAL; 0.72-1.18

RTECS: 9999999VO


ETHYLENE GLYCOL, GLYCOL *96-3*

CAS: 107-21-1

RTECS: KW2975000

Fraction By Weight: 1-4%

OSHA PEL 50 PPM

ACGIH TLV: C 127 MG/CUM

EPA Report Quantity: 1 LB

DOT Report Quantity: 1 LB


2-(2-BUTOXYETHYOXY)-ETHANOL, DIETHYLENE GLYCOL MONOBUTYL

CAS: 112-34-5

RTECS: KJ9100000

Fraction By Weight: 1-20%


SILICA CRYSTALLINE, SILICA (CRISTOBALITE) (SUSPECTED HUMAN

CAS: 14464-46-1

RTECS: VV7325000

Fraction By Weight: 0-0.1%

ACGIH TLV: 0.05 MG/CUM

Hazards

Routes of Entry: Inhalation:YES Skin:NO Ingestion:NO
Reports of Carcinogenicity:NTP:YES IARC:YES OSHA:NO
Health Hazards Acute and Chronic:IRRITATION TO EYES, SKIN & UPPER
RESPIRATORY SYSTEM. LONG TERM EXPOSURE TO HIGH LEVELS OF SILICA
DUST MAY CAUSE SILICOSIS & POSSIBLY CANCER. PROLONGED OVEREXPOSURE
TO SOLVENTS MAY CAUSE ADVERSE EFFECT S TO THE LIVER & URINARY
SYSTEMS.
Explanation of Carcinogenicity:SEE INGREDIENTS
Effects of Overexposure:IRRITATION, HEADACHE, NAUSEA, DIZZINESS,
REDNESS, ITCHING, BURNING SENSATION.

First Aid

First Aid:INHALATION: REMOVE TO FRESH AIR. RESTORE BREATHING. KEEP WARM
& QUIET. SKIN: WASH THOROUGHLY W/SOAP & WATER. EYES: FLUSH W/WATER
FOR 15 MINS. OBTAIN MEDICAL ATTENTION IN ALL CASES.

Fire Fighting

Extinguishing Media:CO2, DRY CHEMICAL, ALCOHOL FOAM.
Fire Fighting Procedures:WEAR FULL PROTECTIVE EQUIPMENT W/SCBA. WATER
SPRAY MAY BE INEFFECTIVE. IF WATER IS USED, FOG NOZZLES ARE
PREFERABLE. USE WATER TO COOL CLOSED CONTAINERS.
Unusual Fire/Explosion Hazard:CLOSED CONTAINERS MAY EXPLODE DUE TO
BUILD UP OF PRESSURE WHEN EXPOSED TO EXTREME HEAT.

Accidental Release

Spill Release Procedures:REMOVE IGNITION SOURCES. VENTILATE & REMOVE
W/INERT ABSORBENT.

Handling

Handling and Storage Precautions:KEEP CONTAINER CLOSED WHEN NOT IN USE.
TRANSFER ONLY TO APPROVED CONTAINERS W/COMPLETE & APPROPRIATE
LABELING. DON'T TAKE INTERNALLY.
Other Precautions:KEEP OUT OF REACH OF CHILDREN. AVOID BREATHING
VAPORS/SPRAY MIST. AVOID CONTACT W/SKIN & EYES.

Exposure Controls

Respiratory Protection:WEAR A PROPERLY FITTED ORGANIC VAPOR/PARTICULATE
RESPIRATOR APPROVED BY NIOSH/MSHA. WHEN SANDING/ABRADING THE DRIED
FILM, WEAR A DUST/MIST RESPIRATOR APPROVED BY NIOSH/MSHA.
Ventilation:LOCAL/GENERAL EXHAUST VENTILATION
Protective Gloves:RECOMMENDED
Eye Protection:SAFETY GLASSES W/UNPERFORATED SIDESHIELD
Work Hygienic Practices:REMOVE/LAUNDER CONTAMINATED CLOTHING BEFORE
REUSE. WASH THOROUGHLY AFTER HANDLING.
Supplemental Safety and Health
PH: 8.2-9.8

Chemical Properties

Boiling Pt:B.P. Text:212-486F
Vapor Density:>1
Spec Gravity:1.12-1.55
pH:(SUPP)
Evaporation Rate & Reference:SLOWER THAN ETHER
Percent Volatiles by Volume:57-81

Stability

Stability Indicator/Materials to Avoid:YES
Hazardous Decomposition Products:BY FIRE: CO, CO2.

Disposal

Waste Disposal Methods:NON-HAZARDOUS. INCINERATE IN APPROVED FACILITY.
DON'T INCINERATE CLOSED CONTAINERS. DISPOSE OF IAW/FEDERAL, STATE &
LOCAL REGULATIONS.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.